A test performed at
ENRJ International, Ltd..
Showed that Homogenized #6 fuel
with 7% water injection at four (4) to seven (7) microns has
burnout times six times greater then regular #6 fuel.
Requiring less residence time
in combustion chamber.
Burner,
is four inch diameter using
natural gas as a heat source.
Eighth inch stainless steel wire was
inserted one inch into sample bottles.
The one on left is regular #6
fuel.
The one on the right is homogenized #6
oil with 7% water by volume at four (4) to seven (7) microns. The
test wires with oil residue were inserted into flame with results
as shown on photograph
The typical #6 fuel on left burned
very slow and produced black
smoke.
The homogenized # 6 oil with7% water
on the right
exploded as it entered the flame,
producing very light brown
smoke.
Contact us at
info@enrjintl.com for additional information |